- Home
- ยป
- Products & Services
- »
- Boiler Water Treatment Chemicals
Boiler Water Treatment Chemicals
Descalant Boiler Chemicals
Minimum Order Quantity: 40 Litre
Product Brochure
Grade Standard | Technical Grade |
Usage/Application | Industrial |
Packaging Size | 35 kg, 50 kg |
Brand | FUSION |
Model No | AQUACLEAN 8001, AQUACLEAN 8001 |
Packaging Type | Drum |
Flammable | Combustible |
Loading Type | Top Loading |
Physical State | Liquid |
Composition /information On Ingredients It Is Balanced Formulation of Sulfamic acid (6%), Hydrochloric acid (5 %) Sodium dichromate (0.5%) and Corrosion inhibitor (0.5%).
Hazards Identification Important Hazards - Toxic. Health Hazard - Toxic if swallowed. Causes severe burns in contact with skin. Causes severe irritation on inhalation. Causes severe irritation or burns in contact with eyes.
First Aid Measures Inhalation :
Inhalation - Move to fresh air. Artificial respiration if required. Seek medical attention.
Skin Contact - Wash immediately with plenty of water. Remove all contaminated clothing immediately. Seek medical attention.
Eye Contact - Flush with plenty of water. Keep eyelids apart. Seek medical attention.
Ingestion - Do not induce vomiting. If conscious then only give 2 -4 cupfuls of water. Seek Medical attention.
Stability and Reactivity :
Condition to Avoid - Keep away from heat and ignition. Contact with metals may evolve flammable Hydrogen gas.
Materials to avoid - Highly reactive with strong bases. Incompatible with materials like cyanides, Sulfides, sulfites and formaldehyde
Hazardous decomposition - Thermal oxidative decomposition produces
Additional Information:
- Item Code: 8001
- Production Capacity: 1000
- Delivery Time: 1-2 Days
- Packaging Details: Can Packing
Boiler Chemicals
Minimum Order Quantity: 40 kg
Product Brochure
Usage/Application | Industrial |
Packaging Details | 50 kg Drum |
Type Of Chemicals | BOILER CHEMICALS |
Function | Corrosion inhibitors |
Packaging Size | 40 KG |
Grade Standard | Technical Grade |
Packaging Type | Can Packing |
Physical State | Liquid |
· Neutralizer
· Antiscalant
· Oxygen Scavenger
· pH Booster
· Hardness Remover
· Sludge Conditioner
·
To ensure clean heat transfer area in steam generating equipment and for optimum efficiency chemical treatment is essential. Fusion Aqua Solutions boiler feed water chemicals include multi-functional products, Antiscalant for various quality water, oxygen scavenger, sludge conditioners, pH & Alkalinity builder, condensate line treatment, fuel additives (liquid| solid)
We consider Service to be a crucial part of the treatment Program. Our Professionals provide Below Mentioned services Free of cost in order to test & stabilize treatment Initiatives.
v System Survey
v Program Selection & Recommendations.
v Application & Monitoring.
v Monthly Water Test Report.
v Treatment Review & Audit.
v Program Optimization.
Oxygen Scavenger High Capacity Boiler Treatment Chemical
Minimum Order Quantity: 35 KG
Product Brochure
Usage/Application | Industrial |
Type Of Chemicals | Boiler Chemical |
Packaging Size | 35,50 Kg |
Grade Standard | Technical Grade |
Packaging Type | Can Packing |
Small, Medium, High Capacity Range Available
Additional Information:
- Item Code: AQUACOOL-1003
- Production Capacity: 500 Kg
pH Booster Boiler Treatment Chemical
Product Brochure
Usage/Application | Industrial |
Grade Standard | Technical Grade |
Packaging Size | 5,10,35,50 Kg Can Packing |
Physical State | Liquid |
Packaging Type | Can Packing |
Form - Liquid
Colour - Clear Colourless Liquid
pH - > 12
Density - 1.00 - 1.08
PH Booster
Product Brochure
Grade | Technical |
Usage/Application | Industrial |
Packaging Size | 5 - 50 kg |
Physical State | Liquid |
Grade Standard | Technical Grade |
Usage | Industrial |
Known for increasing alkalinity and the pH of boiling water, the Boiler water pH booster or alkalinity builder(or multipurpose Boiler Water Treatment Chemical) helps in removing sludge and deposits.
The pH for such is generally at 9.5-10, which prevents corrosion or rusting of boiler tubes.
Aiding in the scaling of boiler tubes, makes such chemicals an economical choice since it saves power and workforce. Its accelerating production ability helps meet targets easily.
This pH booster is a unique alkaline liquid meant to reduce rusting of feed water tanks and parts and increase alkalinity.
Powder RO pH Booster Chemical, pH Booster, Sodium Bicarbonate, For Industrial, Grade Standard: Food Grade. Sodium bicarbonate (IUPAC name: sodium hydrogen carbonate), commonly known as baking soda or bicarbonate of soda, is a chemical compound with the formula NaHCO3.Sulfamic Acid Liquid
Product Brochure
Form | Liquid |
Packaging | 50 Litres Drum |
Packaging Size | 40 kg |
Packaging Type | Can |
Usage/Application | Industrial |
Grade | Technical Grade |
Usage | Industrial |
Physical State | Liquid |
Purity | 64% |
Melting Point | 205 Degree C |
Density | 2.15 g/cm3 |
pH Value | 5-7 |
Additional Information:
- Delivery Time: As per Customer Location we deliver product as possible as.